VidaPeps logo
AX-2026-1827-3R63v13
GHK-Cu 100 mg · Lot CU-100MG-260622-3E · VidaPeps
CRYPTOGRAPHICALLY SEALED
SHA-384: d0ac14aa52886d1d
Scan to verify
PRODUCT ATTRIBUTION
VidaPeps logo
VidaPeps
VidaPeps LLC
vidapeps.com
Brand identity verified
Submitted by: VidaPeps LLC

Originated by VidaPeps LLC, which attests it authorized this test as the brand of record.

Axiom confirmed this brand is a registered Axiom account. This does not confirm the product's origin, chain of custody, or that the brand authorized this specific test.

Open / Print PDF
PASS — All specifications met4 of 4 layers complete
  • L1
    Identity
  • L2
    Purity
  • L3
    Net Peptide Content
  • L4
    Sterility Screen
SAMPLE & VIAL VALIDATION
BrandVidaPeps
ProductGHK-Cu 100 mg
Lot / BatchCU-100MG-260622-3E
Label Claim100 mg lyophilized powder
Matrixlyophilized powder
Sample Count2
Cap ColorRoyal Blue
Crimp ColorSilver / Aluminum
Contents ColorBlue
Seal IntactYes
Conditionsealed, intact

Test Results

Select a test for its full result
Referencewithin ±1 Da of 401.914 DaResult401.918 Da (error 0.004 Da)PASS
Referenceat least 98% (Axiom internal screening criterion (USP 621 guidance))Result99.8%PASS
Referencewithin ±10% of 100 mg and CV at or below 5%Resultmean 101.12 mg over 2 vials, CV 0.64%PASS
ReferenceUSP <71>ResultNo GrowthPASS
REVIEW & DIGITAL SIGNATURES
Analyst
Alana Reeves
ed25519:71c272cb399087363cfe6e34...
Technical Reviewer
Michael Niles
ed25519:72a3831c907b26fcbbc1da03...
Laboratory Director
Daniel Brennan
ed25519:c65dafc61736ee1bf1d2d2dc...
Released Jun 27, 2026, 23:55 UTC
This report is immutable. Any alteration breaks the cryptographic seal. Verify independently at /verify/AX-2026-1827-3R63
REPORTING SCOPE

Results relate only to the item or portion tested. Unless sampling was performed or witnessed by Axiom Analytics, the laboratory does not attest that the submitted sample represents the wider lot or batch. A PASS designation means only that the reported result met the specification shown. It does not establish safety, efficacy, regulatory approval, legality, or suitability for human or animal use.

RESEARCH USE ONLY

All analytical testing, validation reports, and interactive Certificates of Analysis (COAs) provided by Axiom Analytics are intended strictly for Research Use Only (RUO) in in-vitro or laboratory animal model environments. Axiom Analytics does not analyze, validate, evaluate, or make any representations regarding the safety, efficacy, toxicity, or legality of any tested substance for human or animal consumption, veterinary use, clinical diagnostics, food additives, cosmetics, or household applications.

ANALYSIS & ACCREDITATION

Physical instrument analysis is performed within Axiom Analytics' laboratory network, allocated at Axiom's discretion based on method, capacity, and order volume. Axiom Analytics performs sample accession, chain of custody, analytical oversight, and data review, and issues and is responsible for this certificate. Where analysis is subcontracted, the method is performed within the partner laboratory's published ISO/IEC 17025 scope of accreditation for that method, not merely at a laboratory holding ISO/IEC 17025 accreditation. Axiom Analytics does not itself currently hold ISO/IEC 17025 accreditation. The method-validation status of each reported result is identified beside that result. Partner laboratory identities are not disclosed: samples are analyzed under double-blind conditions, identified only by an internal lot ID.

LIMITATION OF LIABILITY

To the maximum extent permitted by applicable law, the cumulative liability of Axiom Analytics, its officers, employees, and third-party laboratory partners to the client or any third party for any claims, losses, damages, or liabilities of any kind (including but not limited to direct, indirect, special, incidental, punitive, or consequential damages) shall be strictly limited to, and shall not exceed, the exact dollar amount paid by the client to Axiom Analytics for the specific individual analytical test run from which the liability arose.