EXAMPLE CERTIFICATE

A real Axiom 8X Comprehensive Certificate of Analysis

This is the exact document your customers receive and verify, with live chromatograms, mass spectra, and reference ranges. Cryptographically sealed and QR-verifiable.

Axiom AnalyticsAxiomAnalytics
Certificate of Analysis · 8X Comprehensive Panel
AX-2026-00041
Issued 2026-06-18
Verify: AX-7K2M-9QPD
ClientExample Research Supply
ProductTirzepatide
Lot / BatchTZ-2026-X9
Label claim15.0 mg/vial
MatrixLyophilized powder
SamplingClient-submitted vial
ALL 8 LAYERS PASS
8 / 8 complete
1
Molecular Mass Fingerprinting
LC-MS/MS, ESI+
4814.9 Da [M+H]+
± 1.0 Da (theor. 4814.5)
CONFIRMED
Identity confirmed
Tirzepatide
1007550250theor. 4814.5obs. 4814.94813.54814.94815.94816.9m/zRelative abundance (%)
2
Homogeneity Profiling
RP-HPLC, 214 nm (USP 621)
99.1% main peak
≥ 98.0%
PASS
100755025099.1%6.82Tirzepatide4.318.0702.14.16.28.310.3Retention time (min)Relative response, % (UV 214 nm)
3
Net Peptide Mass Quantitation
Quantitative HPLC vs reference standard
15.07 mg (mean)
15.0 mg ± 10%
PASS
target 15mean 15.0715.1A14.9B15.2CNet peptide per vial (mg)
15.07 mg PASS
4
Sterility Screen
Rapid molecular microarray screen (NOT USP 71 sterility)
0 CFU
≤ 10 CFU
PASS
limit 10 CFU0 CFU PASS
5
Bacterial Endotoxin
Kinetic chromogenic LAL (USP 85)
0.04 EU/mg
≤ 0.5 EU/mg
PASS
limit 0.5 EU/mg0.04 EU/mg PASS
6
Elemental Catalytic Sweep
ICP-MS (USP 232/233)
All < LOQ
USP 232 parenteral limits
PASS
ElementObservedLimitStatus
Lead (Pb)< 0.5 ppb5000 ppbPASS
Arsenic (As)< 1.0 ppb1500 ppbPASS
Cadmium (Cd)< 0.5 ppb500 ppbPASS
Mercury (Hg)< 1.0 ppb3000 ppbPASS
7
Post-Reconstitution Stability
Forced-degradation, pH + clarity
pH 6.82 · 1.1% degr. · clear
pH 6.5-7.4 · < 5% at 24 h
STABLE
6.82 pH PASS
limit 5%1.1% PASS
8
Fentanyl & Analog Screen
Targeted LC-MS/MS adulterant screen
None detected
Not detected ≥ detection limit
PASS

A harm-reduction research screen for fentanyl and common analogs. Each analyte is reported as detected or not-detected against the method detection limit. This is a research screen, not a validated release assay.

AnalyteDetection limitResult
Fentanyl0.5 ng/mgNOT DETECTED
Acetylfentanyl0.5 ng/mgNOT DETECTED
Carfentanil0.2 ng/mgNOT DETECTED
Analyst
Alana Reeves
ed25519:19e9e88dadaa…
Technical Reviewer
Michael Niles
ed25519:5cc0f0cec554…
Laboratory Director
Daniel Brennan
ed25519:c614761fa11d…
✓ CRYPTOGRAPHICALLY SEALED (ed25519 + SHA-384)
SHA-384: a7f3c1d9e84b2f06…e9d2 · Seal: 9f2a…c7b1
Scan or visit axiomanalyticslab.com/verify/AX-7K2M-9QPD to confirm authenticity.
Any alteration breaks verification.
Axiom Analytics Labs LLC · 2108 N St Ste N, Sacramento, CA 95816, USA · A PASS means the measured result met the stated specification; it does not establish safety, sterility, or regulatory approval. Not ISO/IEC 17025 accredited.

What you (the vendor) get

  • A shareable verification link for every product page
  • Downloadable, branded PDF for records and compliance
  • A QR code buyers scan to confirm authenticity
  • Raw chromatograms and spectra on request

What your customers see

  • Instant confirmation the report is real, not forged
  • Every result charted and explained in plain language
  • No need to trust a screenshot or forwarded PDF
  • Verification comes from our database, not a file