AX-2026-3324-XVG2v1
5-Amino-1-mq 10mg · Lot 5AM-10MG-260805-7C · VidaPeps
CRYPTOGRAPHICALLY SEALED
SHA-384: cfd66d30fae350ed
Scan to verify
PRODUCT ATTRIBUTION
VidaPeps logo
VidaPeps
VidaPeps LLC
vidapeps.com
Brand identity verified
Submitted by: VidaPeps LLC

Originated by VidaPeps LLC, which attests it authorized this test as the brand of record.

Axiom confirmed this brand is a registered Axiom account. This does not confirm the product's origin, chain of custody, or that the brand authorized this specific test.

Open / Print PDF
SAMPLE & VIAL VALIDATION
Validated vial
Vial as received & analyzed
BrandVidaPeps
Product5-Amino-1-mq 10mg
Lot / Batch5AM-10MG-260805-7C
Label Claim10 mg
Matrixlyophilized powder
Sample Count1
Vial Size3R
Cap ColorTranslucent Pink
Crimp ColorSilver / Aluminum
Contents ColorOrange
Seal IntactYes
Conditionsealed, intact
LAYER 1: LC-MS/MS (ESI+)

Molecular Mass Fingerprinting

pass· accredited
Theoretical [M+H]+
159.212 Da
Observed [M+H]+
159.212 Da
Mass Error
0 Da (limit ±1 Da)

Observed & theoretical compared on the average mass basis

Mass spectrum trace not retained for this certificate; identity confirmed by accurate mass (error within tolerance).

Deconvoluted average mass is consistent with the expected molecular mass; identity confirmed.

REVIEW & DIGITAL SIGNATURES
Analyst
Alana Reeves
ed25519:7a2c6732f64edba82134b8b5...
Technical Reviewer
Michael Niles
ed25519:e36efff9e0e1403adbad313e...
Laboratory Director
Daniel Brennan
ed25519:e3e9672c89953d0f9b89df1e...
Released Aug 17, 2026, 18:52 UTC
This report is immutable. Any alteration breaks the cryptographic seal. Verify independently at /verify/AX-2026-3324-XVG2
RESEARCH USE ONLY

All analytical testing, validation reports, and interactive Certificates of Analysis (COAs) provided by Axiom Analytics are intended strictly for Research Use Only (RUO) in in-vitro or laboratory animal model environments. Axiom Analytics does not analyze, validate, evaluate, or make any representations regarding the safety, efficacy, toxicity, or legality of any tested substance for human or animal consumption, veterinary use, clinical diagnostics, food additives, cosmetics, or household applications.

ANALYSIS & ACCREDITATION

Physical instrument analysis is performed at Axiom Analytics' discretion (based on method, capacity, and order volume), either in Axiom's own laboratory under its documented quality system or by an independent partner laboratory engaged under confidentiality. Where analysis is subcontracted, the method is performed within the partner laboratory's published ISO/IEC 17025 scope of accreditation for that method, not merely at a laboratory holding ISO/IEC 17025 accreditation. Axiom Analytics does not itself currently hold ISO/IEC 17025 accreditation. The method-validation status of each reported result is identified beside that result. Partner laboratory identities are not disclosed: samples are analyzed under double-blind conditions, identified only by an internal lot ID.

LIMITATION OF LIABILITY

To the maximum extent permitted by applicable law, the cumulative liability of Axiom Analytics, its officers, employees, and third-party laboratory partners to the client or any third party for any claims, losses, damages, or liabilities of any kind (including but not limited to direct, indirect, special, incidental, punitive, or consequential damages) shall be strictly limited to, and shall not exceed, the exact dollar amount paid by the client to Axiom Analytics for the specific individual analytical test run from which the liability arose.